Lenovo Flex System x440 Compute Node Installation And Service Manual page 848

Table of Contents

Advertisement

User Response:
Complete the following steps:
1. If system failed to boot successfully, DC cycle the system.
2. If system boots to F1 setup, update the UEFI image and reset bank to primary (if required). If the
system boots without error, recovery is complete and no additional action is required.
3. If system fails to boot, or if the firmware update attempt fails, replace the system board.
• I.3868000: [I.3868000] BOFM: System reset performed to reset adapters.
[I.3868000] BOFM: System reset performed to reset adapters.
Severity: Info
User Response:
Complete the following steps:
Information only; no action is required.
• I.3868003: [I.3868003] BOFM: Configuration to large for compatibility mode.
[I.3868003] BOFM: Configuration to large for compatibility mode.
Severity: Info
User Response:
Complete the following steps:
Information only; no action is required.
• I.58015: [I.58015] Memory spare copy initiated.
[I.58015] Memory spare copy initiated.
Severity: Info
User Response:
Complete the following steps:
Information only; no action is required.
• I.580A4: [I.580A4] Memory population change detected.
[I.580A4] Memory population change detected.
Severity: Info
User Response:
Complete the following steps:
Check system event log for uncorrected DIMM failures and replace those DIMMs.
• I.580A5: [I.580A5] Mirror Fail-over complete. DIMM number % has failed over to to the mirrored
copy.
[I.580A5] Mirror Fail-over complete. DIMM number % has failed over to to the mirrored copy.
Severity: Info
User Response:
Complete the following steps:
Check the system-event log for uncorrected DIMM failures and replace those DIMMs.
• I.580A6: [I.580A6] Memory spare copy has completed successfully.