May also be shown as 800706172c02ffff or 0x800706172c02ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0530
User Response
Complete the following steps:
1. Remove the I/O expansion adapter in I/O expansion connector 2.
2. Try to power on the chassis.
– If the chassis successfully powers on, complete the following steps:
a. Check the
compatible with the chassis.
b. Inspect the previously installed components for physical damage.
– If the chassis does not successfully power on or if this is not the first occurrence of this
problem, replace the I/O expansion adapter.
• 80070617-2c03ffff : Sensor Mezz Exp 3 Fault has transitioned to non-recoverable.
A problem was detected in the I/O expansion adapter in I/O expansion connector 3. The adapter is unable
to initialize.
May also be shown as 800706172c03ffff or 0x800706172c03ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0530
User Response
Complete the following steps:
Lenovo Flex System x440 Compute NodeInstallation and Service Guide
326
ServerProven website
to make sure that recently installed components are