Emc And Environmental Type Tests - Siemens SIMATIC NET RUGGEDCOM RST2428P Equipment Manual

Rugged ethernet switches
Table of Contents

Advertisement

6.2

EMC and environmental type tests

The RUGGEDCOM RST2428P has passed the following EMC and environmental tests.
EMC type test for IEC 61850-3
Note
IEC 61850-3 Class 1/Class 2 Conformance
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
RUGGEDCOM RST2428P
Equipment Manual, 10/2023, C79000-G8976-1528-01
In the case of an all fiber port configuration, this product meets all Class 2
requirements. Otherwise, all Class 1 requirements are met for copper ports and
mixed fiber/copper ports.
If the unit contains copper ports, the IEC 61850-3 and IEEE 1613 conformance is
Class 1, during which disturbance errors may occur but recovery is automatic.
If the unit contains all fiber ports, the IEC 61850-3 and IEEE 1613 conformance is
Class 2, during which no disturbance errors will occur.
Test
ESD
Radiated RFI
Burst (fast
transient)
Surge
Induced
(conducted) RFI
Magnetic field
6.2 EMC and environmental type tests
Description
Enclosure contact
Enclosure air
Enclosure ports
Signal ports
DC power ports
AC power ports
Earth ground ports
Signal ports
DC power ports
AC power ports
PoE power ports
Signal ports
DC power ports
AC power ports
Earth ground ports
Enclosure ports
Certification
Test levels
Severity levels
± 8 kV
± 15 kV
20 V/m
± 2 kV at 5
or 100 kHz
± 4 kV at 5
or 100 kHz
± 4 kV at 5
or 100 kHz
± 4 kV at 5
or 100 kHz
± 4 kV line-
to-earth
± 2 kV line-to-line
± 2 kV line-
to-earth
± 1 kV line-to-line
± 4 kV line-
to-earth
± 2 kV line-to-line
± 1 kV line-
to-earth
± 1 kV line-to-line
10 V
10 V
10 V
10 V
100 A/m for 3 min
4
4
a
Note
a
Note
4
4
4
4
3
4
2
3
3
3
3
5
71