Siemens SIMATIC NET RUGGEDCOM RSG2100F Installation Manual
Siemens SIMATIC NET RUGGEDCOM RSG2100F Installation Manual

Siemens SIMATIC NET RUGGEDCOM RSG2100F Installation Manual

Hide thumbs Also See for SIMATIC NET RUGGEDCOM RSG2100F:

Advertisement

Quick Links

Edition
04/2022
Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM RSG2100F
https://www.siemens.com/ruggedcom

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM RSG2100F

  • Page 1 Edition 04/2022 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RSG2100F https://www.siemens.com/ruggedcom...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RSG2100F Communication Ports Technical Specifications Installation Manual Certification 04/2022 C79000-G8976-1344-11...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................vi Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 3 Decommissioning and Disposal ................3 Cabling Recommendations ..................
  • Page 5 Table of Contents Fiber Optic Ethernet Ports ................... 25 SFP Transceivers ....................26 GBIC Optic Ethernet Ports ..................27 4.4.1 Installing a GBIC Optical Port ................27 4.4.2 Removing a GBIC Optical Port ................29 Technical Specifications ...................... 31 Power Supply Specifications ................31 Failsafe Relay Specifications ................
  • Page 6: Preface

    SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document. The glossary is available online via Siemens Industry Online Support (SIOS) at: https://support.industry.siemens.com/cs/ww/en/view/50305045 Accessing Documentation The latest user documentation for RUGGEDCOM RSG2100F is available online at https://support.industry.siemens.com.
  • Page 7: Warranty

    Preface Warranty Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 8: Contacting Siemens

    Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RSG2100F Installation Manual, 04/2022, C79000-G8976-1344-11...
  • Page 10: Introduction

    Introduction The RUGGEDCOM RSG2100F is a rugged, fully managed, modular Ethernet switch specifically designed to operate reliably in electrically harsh and climatically demanding utility substation, railway and industrial environments. The RUGGEDCOM RSG2100F’s superior rugged hardware design coupled with the embedded Rugged Operating System (ROS) provides improved system reliability and advanced cyber security and networking features, making it ideally suited for creating Ethernet networks for mission-critical, real-time, control applications.
  • Page 11: Description

    Introduction 1.2 Description Universal Power Supply Options • Fully integrated, dual-redundant (optional) power supplies • Universal high-voltage range: 88-300 VDC or 85-264 VAC • Screw or pluggable terminal blocks for reliable, maintenance-free connections • CSA/UL 62368-1 safety approved to 85 °C (185 °F) Description The RUGGEDCOM RSG2100F features various ports, controls and indicator LEDs on the display panel for connecting, configuring and troubleshooting the device.
  • Page 12: Required Tools And Materials

    Introduction 1.3 Required Tools and Materials Mode Color/State Description Green (Blinking) 1000 Mbps Orange (Solid) 10 Mbps No link detected Display Mode Indicator LEDs The display mode indicator LEDs indicate the current display mode for the port status indicator LEDs (i.e. Status, Duplex or Speed). Mode Button The Mode button sets the display mode for the port status indicator LEDs (i.e.
  • Page 13: Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 14: Supported Fiber Optic Cables

    NOTICE Worn, damaged or missing seals must be replaced immediately. Replacement seals are available for purchase from Siemens. For more information, contact a Siemens Sales representative. There are three ways to determine if a security seal has been tampered with: •...
  • Page 15 • Residue left by the seal is visible on the device under ultra-violet light For information about the placement of security seals, refer to the "RUGGEDCOM RSG2100F FIPS 140-2 Non-Proprietary Security Policy [https:// support.industry.siemens.com/cs/ww/en/view/109757984]". RUGGEDCOM RSG2100F Installation Manual, 04/2022, C79000-G8976-1344-11...
  • Page 16: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 17: General Procedure

    Visually inspect each item in the package for any physical damage. Verify all items are included. Note If any item is missing or damaged, contact Siemens for assistance. Installing the Device in Hazardous Locations The RUGGEDCOM RSG2100F is designed to comply with the safety standards...
  • Page 18 Installing the Device 2.3 Installing the Device in Hazardous Locations Special Conditions for Safe Use When installing the device in a hazardous location, note the following special conditions for safe use according to the Canadian Standards Association (CSA): • The equipment shall be installed in an enclosure that is considered to be not accessible in normal operation without the use of a tool providing a degree of protection of not less than IP54 according to CSA/UL/IEC/EN 60079-0 and CSA/ UL/IEC/EN 60079-15.
  • Page 19: Mounting The Device

    Installing the Device 2.4 Mounting the Device Mounting the Device The RUGGEDCOM RSG2100F is designed for maximum mounting and display flexibility. It can be equipped with connectors that allow it to be installed in a 48 cm (19 in) rack, 35 mm (1.4 in) DIN rail, or directly on a panel. NOTICE Heat generated by the device is channeled outwards from the enclosure.
  • Page 20 Installing the Device 2.4.1 Mounting the Device to a Rack • Do not exceed the maximum number of devices or weight restrictions specified by the rack manufacturer. • Do not overload the supply circuit. Refer to the over-current protection and power supply ratings specified by the rack manufacturer. •...
  • Page 21: 2.4.2 Mounting The Device On A Din Rail

    Installing the Device 2.4.2 Mounting the Device on a DIN Rail 2.4.2 Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RSG2100F can be equipped with panel/ DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
  • Page 22: Connecting The Failsafe Alarm Relay

    Installing the Device 2.5 Connecting the Failsafe Alarm Relay To mount the device to a panel, do the following: Place the device against the panel and align the adapters with the mounting holes. Screw Panel/DIN Rail Adapter Figure 2.4 Panel Mounting Install the supplied screws to secure the adapters to the panel. Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions.
  • Page 23: Connecting Power

    Installing the Device 2.6 Connecting Power Normally Open Common Normally Closed Figure 2.5 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RSG2100F supports a single or dual redundant AC and/or DC power supplies. The RUGGEDCOM RSG2100F can be equipped with either a screw-type or pluggable terminal block, which provides power to both power supplies.
  • Page 24: 2.6.1 Connecting Ac Or Dc Power

    Installing the Device 2.6.1 Connecting AC or DC Power • Equipment must be installed according to applicable local wiring codes and standards. 2.6.1 Connecting AC or DC Power To connect a single high AC, high DC or low DC power supply to the device, do the following: NOTICE Electrical hazard –...
  • Page 25 Installing the Device 2.6.1 Connecting AC or DC Power Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block. Screw-Type Terminal Block Pluggable Terminal Block Jumper Positive/Live (+/L) Terminal Negative/Neutral (-/N) Terminal (-/N) Surge Ground Terminal Chassis Ground Terminal Chassis Ground Connection Figure 2.6...
  • Page 26: 2.6.2 Wiring Examples

    Installing the Device 2.6.2 Wiring Examples Using a #6 ring lug and #6-32 screw, secure the ground terminal on the power source to the chassis ground connection on the device. Make sure the lug is tightened to 1.7 N·m (15 lbf·in). Stainless Steel Stud #6-32 Screw #6 Ring Lug...
  • Page 27 Installing the Device 2.6.2 Wiring Examples Figure 2.8 Single AC Power Supply Figure 2.9 Single DC Power Supply RUGGEDCOM RSG2100F Installation Manual, 04/2022, C79000-G8976-1344-11...
  • Page 28 Installing the Device 2.6.2 Wiring Examples Figure 2.10 Dual AC Power Supply Figure 2.11 Dual DC Power Supply RUGGEDCOM RSG2100F Installation Manual, 04/2022, C79000-G8976-1344-11...
  • Page 29 Installing the Device 2.6.2 Wiring Examples Figure 2.12 Dual AC/DC Power Supply RUGGEDCOM RSG2100F Installation Manual, 04/2022, C79000-G8976-1344-11...
  • Page 30: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RSG2100F console and Web interfaces on the device. For more detailed instructions, refer to the "RUGGEDCOMROS Configuration Manual" for the RUGGEDCOM RSG2100F.
  • Page 31: Configuring The Device

    Device Management 3.2 Configuring the Device Name Description Comment RJ45 Male DB9 Female Read to Send   Ring Indicator   The DSR, DCD and DTR pins are connected together internally. The CTS and RTS pins are connected together internally. RI is not connected. Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RSG2100F console and Web interfaces via the device's...
  • Page 32: Communication Ports

    Communication Ports The RUGGEDCOM RSG2100F can be equipped with various types of communication ports to enhance its abilities and performance. Module Assignment Figure 4.1 Module Assignment Each type of module has a specific location in the RUGGEDCOM RSG2100F chassis: • Slot 5 supports a pair of Gigabit Ethernet (1 Gbps) ports •...
  • Page 33: Copper Ethernet Ports

    Communication Ports 4.1 Copper Ethernet Ports Port LED Figure 4.2 Port LEDs LED State Description Yellow (Solid) Link established Yellow (Blinking) Link activity No link detected Copper Ethernet Ports The RUGGEDCOM RSG2100F supports several 10/100/1000Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with either RJ45 or Micro-D male connectors.
  • Page 34: Fiber Optic Ethernet Ports

    Communication Ports 4.2 Fiber Optic Ethernet Ports Name Description 10/100Base-TX 1000Base-TX Reserved (Do Not Connect) BI_DC- Receive Data- or Bi- Directional Pair C- BI_DB- Transmit Data- or Bi- Directional Pair B- Reserved (Do Not Connect) BI_DD+ Receive Data- or Bi- Directional Pair D+ Reserved (Do Not Connect) BI_DD- Receive Data- or Bi-...
  • Page 35: Sfp Transceivers

    SFP Transceivers The RUGGEDCOM RSG2100F supports up to two Small Form-Factor Pluggable (SFP) transceiver sockets, which are compatible with a wide array of SFP transceivers available from Siemens. LEDs Each socket features an LED that indicates its link state. State...
  • Page 36: Gbic Optic Ethernet Ports

    Communication Ports 4.4 GBIC Optic Ethernet Ports IMPORTANT Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liability as a result of performance issues related in whole or in part to third-party components. GBIC Optic Ethernet Ports GBIC (Gigabit Interface Converter) optic Ethernet ports are available with SC (Standard or Subscriber Connector) connectors.
  • Page 37 Communication Ports 4.4.1 Installing a GBIC Optical Port NOTICE Only install GBIC optical ports that are compatible with the RUGGEDCOM RSG2100F. Make sure all potential electrostatic build-up has been properly discharged to prevent electrostatic discharges (ESD). This can be accomplished by wearing an ESD-preventive wrist strap connected to either the chassis ground connector or a bare metal surface on the router/switch.
  • Page 38: Removing A Gbic Optical Port

    Communication Ports 4.4.2 Removing a GBIC Optical Port Connect the cable to a network and observe the LED associated with the port. For more information about the LED, refer to "Communication Ports (Page 23)". 4.4.2 Removing a GBIC Optical Port To remove an GBIC optical port, do the following: WARNING Explosion hazard –...
  • Page 39 Communication Ports 4.4.2 Removing a GBIC Optical Port Store the port in an ESD-safe bag or other suitable ESD-safe environment, free from moisture and stored at the proper temperature (-40 to 85 °C or -40 to 185 °F). Insert a dust plug into the socket opening to prevent the ingress of dust and dirt. RUGGEDCOM RSG2100F Installation Manual, 04/2022, C79000-G8976-1344-11...
  • Page 40: Technical Specifications

    Technical Specifications This section details the specifications and operating conditions of the device. Power Supply Specifications The RUGGEDCOM RSG2100F can be equipped with the following power supplies: NOTICE Electrical hazard – risk of power supply failure or damage to the device Make sure power input to the device is within the specified input range.
  • Page 41: Failsafe Relay Specifications

    RUGGEDCOM RSG2100F. Note • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. RUGGEDCOM RSG2100F Installation Manual, 04/2022, C79000-G8976-1344-11...
  • Page 42: Fiber Optic Ethernet Port Specifications

    14.2 Typical. Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a Siemens sales associates when determining maximum distances. Fast Ethernet (10/100 Mbps) Optical Specifications Mode...
  • Page 43 All optical power numbers are listed as dBm averages. Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associates when determining maximum segment distances. GBIC Gigabit (1 Gbps) Transceiver Specifications Note GBIC transceivers have a temperature range of -40 to 85 °C (-40 to 185 °F), unless...
  • Page 44: Operating Environment

    Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associates when determining maximum segment distances. Operating temperature range of -20 to 85 °C (-4 to 185 °F).
  • Page 45 Technical Specifications 5.8 Dimension Drawings 438.15 Figure 5.1 Overall Dimensions RUGGEDCOM RSG2100F Installation Manual, 04/2022, C79000-G8976-1344-11...
  • Page 46 Technical Specifications 5.8 Dimension Drawings 32.77 21.08 11.68 479.29 470.4 461.0 Figure 5.2 Rack Mount Dimensions RUGGEDCOM RSG2100F Installation Manual, 04/2022, C79000-G8976-1344-11...
  • Page 47 Technical Specifications 5.8 Dimension Drawings 11.7 10.4 476.3 486.4 Figure 5.3 Panel and DIN Rail Mount Dimensions RUGGEDCOM RSG2100F Installation Manual, 04/2022, C79000-G8976-1344-11...
  • Page 48: Certification

    Certification The RUGGEDCOM RSG2100F device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. Approvals This section details the standards to which the RUGGEDCOM RSG2100F complies. 6.1.1 This device meets the requirements of the following Canadian Standards Association (CSA) standards under certificate 16.70068356: •...
  • Page 49: 6.1.2 Csa/Sira

    For the maximum ambient temperature, refer to the hazardous location label affixed to the device. 6.1.3 European Union (EU) This device is declared by Siemens Canada Ltd. to comply with essential requirements and other relevant provisions of the following EU directives: RUGGEDCOM RSG2100F Installation Manual, 04/2022, C79000-G8976-1344-11...
  • Page 50: Fcc

    Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd.. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 51: 6.1.5 Fda/Cdrh

    Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.6 ISED This device is declared by Siemens Canada Ltd. to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.7...
  • Page 52: Emc And Environmental Type Tests

    Certification 6.2 EMC and Environmental Type Tests • IEC 61000-6-2 Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity for Industrial Environments • IEC 61850-3 Communication Networks and Systems in Substations – Part 3: General Requirements • EN 50121-4 Railway Applications – Electromagnetic Compatibility – Emission and Immunity of the Signaling and Telecommunications Apparatus EMC and Environmental Type Tests The RUGGEDCOM RSG2100F has passed the following Electromagnetic Compatibility...
  • Page 53 DC Power Ports 5 kV   AC Power Ports   Siemens-specified severity levels EMC Immunity Type Tests per IEEE 1613 Note RUGGEDCOM products meet Class 1 requirements for copper Ethernet configurations and Class 2 for fiber Ethernet configurations. Class 1 allows for...
  • Page 54 Certification 6.2 EMC and Environmental Type Tests temporary communication loss, while Class 2 requires error-free and interrupted communications. Description Test Levels Enclosure Contact ±2 kV ±4 kV ±8 kV Enclosure Air ±4 kV ±8 kV ±15 kV Radiated RFI Enclosure Ports 35 V/m Fast Transient Signal Ports...
  • Page 55 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Level Humidity (Damp Test Cab 10 days @ 55 °C (131 °F)   60068-2-78 Heat, Steady State) and 93% Relative Humidity Change of Temperature Test Nb 5 Cycles, -40 to 85°  ...
  • Page 56 For more information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens Canada Ltd. Digital Industries Process Automation 300 Applewood Crescent Concord, Ontario, L4K 4E5 Canada © 2022 Siemens Canada Ltd. Subject to change...

Table of Contents