Siemens SIMATIC NET RUGGEDCOM RST2428P Equipment Manual page 39

Rugged ethernet switches
Table of Contents

Advertisement

Installing the device
2.5.2 Installing/removing power supply modules
with a LO DC power supply module, an additional redesign of the power module slot
is also required.
The device must be powered down before any redesign of the power supply module
wiring is conducted.
A system restart is required following any redesign of the power supply module
wiring.
Required tools/hardware
Torx T10 screwdriver
1.5 mm (1/16 in) Allen key
Removing a power supply module
To remove a power supply module, do the following:
Electrocution hazard – risk of serious personal injury or death
Make sure power to the device is turned off before servicing the power supply
terminal.
1.
2.
3.
Installing a power supply module
There are four scenarios in which a power module can be installed.
30
Hardware
DANGER
Using a Torx T10 screwdriver, loosen the screw that secures the module to the
chassis until the module can be removed.
Figure 2.10
Removing a power supply module
Slide the module out of the chassis.
Install a new power supply module or a blank module to prevent the ingress of
dust and dirt.
Quantity
1
For removing/installing power modules.
1
For removing/installing the power
supply module set screw.