Certification
6.2 MIL-STD Ratings
6.2

MIL-STD Ratings

MIL-STD 901D
MIL-STD 461F
DOD-STD 1399
MIL-STD 1399 (Section 300B)
MIL-STD-167-1A
6.3

EMC and Environmental Type Tests

The RUGGEDCOM MX5000 has passed the following EMC and environmental tests.
IEC 61850-3 EMC Type Tests
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-29
IEC 61000-4-11
50
Standard
Test
ESD
Radiated RFI
Burst (Fast Transient)
Surge
Induced
(Conducted) RFI
Magnetic Field
Voltage Dips
& Interrupts
Voltage Dips
& Interrupts
Description
Shock (Hard-Mounted)
EMI
Magnetic Field (DC Magnetic
Exposure)
Electrical Power Interface
Standards for Shipboard Systems
Mechanical Vibrations of
Shipboard Equipment
Description
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal ports
DC Power ports
AC Power ports
Earth ground ports
Signal ports
DC Power ports
AC Power ports
Signal ports
D.C Power ports
AC Power ports
Earth ground ports
Enclosure Ports
DC Power ports
AC Power ports
AC Power ports
Comments
Approved
Approved
Approved
Approved
Approved
Test Levels
+/- 8 kV
+/- 15 kV
20 V/m
+/- 4 kV @ 2.5 kHz
+/- 4 kV
+/- 4 kV
+/- 4 kV
+/- 4 kV line-to-earth,
+/- 2 kV line-to-line
+/- 2 kV line-to-earth,
+/- 1 kV line-to-line
+/- 4 kV line-to-earth,
+/- 2 kV line-to-line
10 V
10V
10V
10V
100 A/m
1000 A/m for 1 s
30% for 0.1 s, 60% for
0.1 s, 100% for 0.05 s
30% for 1 period,
60% for 50 periods
100% for 5 periods,
100% for 50 periods
RUGGEDCOM MX5000
Equipment Manual, 11/2023, C79000-G8976-1059-16
Severity
Levels
4
4
a
Note
a
Note
4
4
4
4
3
4
3
3
3
3
 