Emc And Environmental Type Tests - Siemens SIMATIC NET RUGGEDCOM PSG907R Installation Manual

Rugged ethernet switches
Table of Contents

Advertisement

Certification
6.2 EMC and Environmental Type Tests
EN50121-4
Railway applications – Electromagnetic Compatibility – Emission and Immunity
of the Signaling and Telecommunications Apparatus
EN50121-3-2
Railway applications – Electromagnetic Compatibility – Rolling Stock Apparatus
EN 50155
Railway applications – Rolling stock – Electronic equipment
6.2

EMC and Environmental Type Tests

The RUGGEDCOM RSG907R has passed the following Electromagnetic Compatibility
(EMC) and environmental tests.
EMC Type Tests
Test
IEC
61000-4-2
IEC
61000-4-3
IEC
61000-4-4
IEC
61000-4-5
IEC
61000-4-6
IEC
61000-4-8
42
All manuals and user guides at all-guidesbox.com
Description
ESD
Enclosure Air
Radiated RFI
Burst (Fast Transient)
Ground Ports
Surge
Induced (Conducted) RFI
Ground Ports
Magnetic Field
Test Levels
Enclosure
± 8 kV
Contact
± 15 kV
Enclosure
20 V/m
Ports
Signal Ports
± 4 kV @ 2.5 kHz, 5 kHz
DC Power
± 4 kV @ 2.5 kHz, 5 kHz
Ports
AC Power
± 4 kV @ 2.5 kHz, 5 kHz
Ports
Earth
± 4 kV @ 2.5 kHz, 5 kHz
Signal Ports
± 4 kV Line-to-Ground
± 2 kV Line-to-Line
DC Power
± 2 kV Line-to-Ground
Ports
± 1 kV Line-to-Line
AC Power
± 4 kV Line-to-Ground
Ports
± 2 kV Line-to-Line
Signal Ports
10 V
DC Power
10 V
Ports
AC Power
10 V
Ports
Earth
10 V
Enclosure
100 A/m Continuous
Ports
1000 A/m for 1 s
Installation Manual, 02/2021, C79000-G8976-1387-12
Severity
Levels
4
4
4
4
4
4
4
3
4
3
3
3
3
 
RUGGEDCOM RSG907R

Advertisement

Table of Contents
loading

Table of Contents