Select The Teach Mode Using The Remote Input - Banner Q5X Instruction Manual

Laser triangulation sensor with analog outputs and io­link
Hide thumbs Also See for Q5X:
Table of Contents

Advertisement

The remote input provides limited programming options. Connect the gray wire to 24 V DC with a remote switch connected
between the wire and ground. Pulse the remote input according to the diagram and the instructions provided in this manual.
The remote input will be either active high or active low depending on the polarity setting. If the polarity is set to def or PNP,
the remote input is active high. If the polarity is set to NPN, the remote input is active low.
The length of the individual programming pulses is equal to the value T where 0.04 seconds ≤ T ≤ 0.8 seconds.
Exit remote programming modes by activating the remote input for longer than 2 seconds.
Remote
Input Wire Function = Set
Input
wiring diagram
1x
2x
4x
8x

Select the TEACH Mode Using the Remote Input

Follow the instructions below to choose a specific TEACH Mode using Remote Input.
1.
Access the TEACH selection.
Double­pulse the remote input.
Select the desired TEACH mode.
2.
Pulses
1
June 22, 2023
Q5X Laser Triangulation Sensor With Analog Outputs And IO-Link Instruction Manual
Remote Input Map
1x
1x
2x
Dynamic background suppression
One-point window (foreground suppression)
3x
4x
One-point background suppression
5x
Dual, intensity + distance
Button Lock
1x
Button Unlock (uloc)
2x
Button Lock (loc)
3x
Operator Lock (OLoc)
Reset to Factory Defaults (maintain remote input = SET)
Action
Action
TEACH Mode
T
Two­point static background suppres­
sion
Continued on page 36
© Banner Engineering Corp.
T
T
tch displays.
T
The selected TEACH method displays for a
few seconds and the sensor returns to Run
mode.
Result
Result
35

Advertisement

Table of Contents
loading

Table of Contents