Method
Push Button
Present the second target. The sensor­to­target distance must be with­
in the sensor's range.
Remote Input
Teach the sensor at the 10 V (20 mA) distance.
5.
Method
Push Button
Press TEACH to teach the target.
Remote Input
Single­pulse the remote input.
If the same target is taught both times, Lo and SPAn flash alternately on the display, the 10 V (20 mA) value is automatically
adjusted to maintain the minimum window size, the new distance quickly flashes four times, and the sensor returns to Run
mode.
It is possible to skip teaching the 0 V (4mA) and/or the 10 V (20mA) point and continue to use the existing setting. At the ap­
plicable teach step, when using the push button, hold - for four seconds. The sensor displays SAVE and then flashes the ex­
isting value. When using the remote input, double­pulse the remote input.
One­Point (1­PT) TEACH (Channel 1 Only)
One-point TEACH mode defines the span of the analog output. One-point TEACH also defines the 5 V (12 mA) midpoint of
the analog output to center the analog output around a reference target position.
Press and Hold
> 2s
2
1
The sensor must be set to tch = 1-Pt to use the following instructions. To program the sensor using remote input, remote in­
put must be enabled (inPt = SEt).
Present the target at the desired 5 V (12 mA) distance.
1.
Method
Push Button
Present the first target. The sensor-to-target distance must be within
the sensor's range.
Remote Input
Start the TEACH mode.
2.
Method
Push Button
Press and hold TEACH for longer than 2 seconds.
June 22, 2023
Q5X Laser Triangulation Sensor With Analog Outputs And IO-Link Instruction Manual
Action
Action
One­Point Window
Press again
3
Action
Action
Continued on page 18
© Banner Engineering Corp.
SEt and 10 U flash alternately on the
display. The 2­Pt indicator flashes.
The new switch point flashes rapidly
T
and the sensor returns to Run mode.
5 V
10 V
5 V
0 V
The target's measurement value dis­
plays.
SEt and 5 U flash alternately on the
display. The 1­Pt indicator flashes.
Result
Result
10 V
5 V
0 V
Result
Result
17