When one of the timing delay options is chosen, the sensor returns to the Setup menu and additional options become avail­
able to set the parameter(s):
dLAY
ond—On delay
oFd—Off delay
1Sho
dt2—One­shot delay timer
For the one-shot delay timer:
LO = On pulse when a target is detected inside of the
switch point(s)
DO = On pulse when a target is detected outside of the
switch point(s)
Delay Timers
Use these menus to set the delay timers. These menus are available only if an output timing delay is selected.
For ond and oFd, the default is 0.
For dt2, the default is 10 milliseconds for all response speeds.
Use + and - to scroll through the values. Millisecond values do not include the decimal point; seconds values include the dec­
imal point.
Value: 1 ms to 90 s or 10 ms to 90 s, depending on response speed setting.
Totalizer (totL)
The totalizer function changes the output only after counting a designated number of targets.
After selecting this function, dt2 becomes available to define the output duration and tot2 to define required number of counts
before the output changes.
For tot2, the default is 1 count and the maximum is 9999 counts.
For dt2, the default is 10 milliseconds. Use + and - to scroll through the values. Values in millisecond do not include the deci­
mal point; values in seconds include the decimal point.
Values include 1 ms to 90 s or 10 ms to 90 s, depending on the response speed setting.
From Run mode, press SELECT to change the display to show the current totalizer count. Pressing SELECT again changes
the display back to the measured distance.
The totalizer count automatically resets after re­teaching the switch point distance or turning the sensor off.
30
Output
OFF Delay
D
ON Delay
1-Shot
D
Output Timing Delays
D
D
D
Time
totL
dt2—Output duration
tot2—Number of counts before an output change
© Banner Engineering Corp.
ON
OFF
D
(D = 1ms - 90.0s)
June 22, 2023