Hysteresis (Hys2); Zero Reference Location (Zero) - Banner Q5X Instruction Manual

Laser triangulation sensor with analog outputs and io­link
Hide thumbs Also See for Q5X:
Table of Contents

Advertisement

Hysteresis (hYS2)

Use this menu to set the hysteresis distance around the switch point.
Auto (The sensor automatically selects a recommended minimum hysteresis distance relative to the current switch point dis­
tance) to 300 (enter a user­selectable value (cm) of hysteresis distance relative to the current switch point distance).
Set Distance—The distance from the reference surface that allows stable use, including the effects of temperature and volt­
age, to the (standard) sensing object transit position. This is approximately 70% to 80% of the normal (rated) sensing dis­
tance.
Hysteresis (Differential Travel)—With respect to the distance between the standard sensing object and the sensor, the differ­
ence between the distance at which the sensor operates and the distance at which the sensor resets.
Smaller hysteresis values cause the output to switch state with less differential travel. A larger hysteresis value makes the
output state to remain unchanged with larger differential travel. Negative hysteresis values allow the operator to move the
hysteresis to either side of the switch point.

Zero Reference Location (ZEro)

Use this menu to select the zero­reference location. Changing the zero­reference location only affects the readout on the dis­
play and does not affect the output.
The default is nEAr, 0 = the front of the sensor. This menu is not available in dual (intensity + distance) mode.
June 22, 2023
Q5X Laser Triangulation Sensor With Analog Outputs And IO-Link Instruction Manual
Set distance
Set Distance
Hysteresis (differential travel)
OFF
ON
Hysteresis
© Banner Engineering Corp.
31