Teach Mode (Discrete) - Banner Q5X Instruction Manual

Laser triangulation sensor with analog outputs and io­link
Hide thumbs Also See for Q5X:
Table of Contents

Advertisement

Q5X Laser Triangulation Sensor With Analog Outputs And IO-Link Instruction Manual
Method
Remote Input
Teach the sensor the 5 V (12 mA) midpoint.
3.
Method
Push Button
Remote Input

TEACH Mode (Discrete)

Use this menu to select the TEACH mode. The default is two­point TEACH. Channel 2 is discrete only.
The number that follows tch on the display indicates which channel is selected.
2-Pt—Two­point static TEACH
dYn—Dynamic background suppression
FGS—One­point window (foreground suppression)
bGS—One­point background suppression
duAL—Dual (intensity + distance) window
After the TEACH mode is selected, from Run mode, press and hold TEACH for longer than 2 seconds to start the TEACH
mode and program the sensor.
Two­Point Static Background Suppression (2­Pt) (Channel 2 Only)
Two­point TEACH sets a single switch point. The sensor sets the switch point between two taught target distances, relative
to the shifted origin location.
The sensor must be set to tch = 2-Pt to use the following instructions. To program the sensor using remote input, remote in­
put must be enabled (inPt = SEt).
Present the target.
1.
Method
Push Button
Remote Input
2.
Start the TEACH mode.
18
No action is required.
Press TEACH to teach the target.
Single­pulse the remote input.
Two-Point Static Background Suppression (Light Operate shown)
2
1
Present the first target. The sensor-to-target distance must be within the
sensor's range.
Continued from page 17
Action
Action
T
3
Action
© Banner Engineering Corp.
Result
N/A
Result
The measurement value flashes
briefly, and the sensor returns to Run
mode.
5
4
Result
The target's measurement value displays.
June 22, 2023

Advertisement

Table of Contents
loading