Lateral Entry Response
Lateral entry to the Q5X
When lateral entry needs to be considered, the lateral entry response is added to calculate the total response time.
NOTE: The Q5X uses a dynamic measurement rate, so these response times are worstcase.
Output Timing Delays
Use this menu to select the output timing delay to be set.
On and off delay timers can be used together. The default is no delay. For Channel 2, this menu is available when the output
is set to light operate or dark operate.
The number that follows dLY on the display indicates which channel is selected.
oFF—No delay
dLAY—Delay—enables the selection of on and off delay timers
1Sho —Oneshot—enables a oneshot, fixed output pulse duration
totL— Totalizer—enables an output after a defined number of targets are counted