Output (Out1 And Out2); Teach Mode (Tch1 And Tch2); Time Selection (Tne1 And Tne2) - Banner Q5X Instruction Manual

Laser triangulation sensor with dual mode and io-link for jam
Hide thumbs Also See for Q5X:
Table of Contents

Advertisement

Q5X Laser Triangulation Sensor With Dual Mode And IO-Link For Jam Detection Instruction Manual

Output (out1 and out2)

The Output 1 and Output 2 menus differ between Channel 1 and Channel 2. 
NOTE: The number that follows out on the display indicates which channel is selected. 
The Output 1 menu is available in Channel 1. Use this menu to select light operate (LO) or dark operate (DO). The default
output configuration is light operate. To switch between light operate and dark operate, select the desired menu option.
—Light operate 
—Dark operate 
The Output 2 menu is available in Channel 2. Use this menu to set the output configuration for Channel 2. The default is light
operate.
—Light operate 
—Dark operate 
—Complementary to output 1 
—Remote TEACH input 
—Laser off when pulled high 
—Laser on when pulled high 
—Master sync line output for two-sensor cross-talk avoidance 
—Slave sync line output for two-sensor cross-talk avoidance 
—Pulse Frequency Modulation (PFM) output (see "Pulse Frequency Modulation (PFM) Output (PULS)" on
page
37) 
To configure the sensor for master-slave operation, see "Sync Master/Slave " on page
TEACH Mode (tch1 and tch2) 
Use this menu to select the TEACH mode. The default is two-point TEACH. For Channel 2, this menu is available when the
output is set to light operate or dark operate.
NOTE: The number that follows tch on the display indicates which channel is selected. 
—Two-point static background suppression 
—Dynamic background suppression 
—One-point window (foreground suppression) 
—One-point background suppression 
—Dual (intensity + distance) window 
—Jam retroreflective 
—Jam background suppression 
After the TEACH mode is selected, from Run mode, press and hold TEACH for longer than 2 seconds to start the TEACH 
mode and program the sensor. See "TEACH Procedures " on page
instructions. 
Time Selection (tnE1 and tnE2)  
Use this menu to set the amount of time the sensor must see a jam condition before the output changes. 
Increase or decrease the time based on the speed of the conveyor and the length of the longest target. The default time is 2
seconds and is suitable for most applications. If the time needs to be increased, Banner recommends setting the Time
Selection equal to the amount of time it takes two of the longest packages to pass back to back in front of the sensor. 
 
 
18
27 for additional information and remote input TEACH 
© Banner Engineering Corp.
37. 
July 10, 2023
 

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q5xklaf2000-q8-jam

Table of Contents