JLG ES1932 Operation & Safety Manual page 84

Table of Contents

Advertisement

Accessories
SkySense is intended to assist the operator. SkySense may not detect certain
objects depending on shape, type of material, or orientation of the object to the
sensors. It is the operator's responsibility to be aware of their surroundings at all
times.
Note: SkySense is not active when operating the machine from the ground controls.
5.12.2
Preparation and Inspection
Pre-Operation Inspection:
1. Inspect each of the SkySense tubes for dents, cracks, or other damage.
2. Inspect each SkySense sensor for any damage to the housing or sensor.
To test the SkySense system:
1. Ensure there are no obstructions within 10 feet around or above the platform and
the machine is on a smooth, firm surface within the limits of the maximum
operating slope.
2. From the platform control console, lift and lower the platform.
3. Place a hand or object above one of the sensors, then lift up the platform.
Platform movement should stop, the LED indicator should be red, and the alarm
should sound. If the alarm is muted, the mute button light should be red.
4. Release the joystick and enable switch.
5. Place a hand or object above one of the sensors. Press the override button on the
notification unit and lift the platform. The platform should lift, the LED indicator
should be red, and the alarm should sound. If the alarm is muted, the mute button
light should be red.
6. Remove hand or object from the sensor zone, then release the joystick and enable
switch. Lower the platform to stowed.
7. Lift the platform with no hand or object above the sensor. The platform should lift
without interruption.
8. Lower the platform to stowed.
84