Figure 2 Remove the Waste Toner Full Sensor
Revised
Phaser 4600/4620/4622 Printer Service Manual
REP 9.7 Pipe Assembly
Parts List on
PL 9.15 Item 2
Removal
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
1.
Remove the Duplex Unit,
REP
2.
Remove the Waste Toner Cartridge.
3.
Remove the Left Cover,
REP
4.
Disconnect P/J29 from the bias contact cover.
5.
Remove 5 screws (metal) that secure the bias contact cover to the chassis,
Figure 1 Remove the bias contact cover
6.
Remove 2 screws (Gold, metal) that secure the Pipe Assembly.
7.
Pull the assembly from the chassis to remove,
04/2016
4-85
WARNING
10.1.
28.3.
Figure
2.
4 Repairs and Adjustments
REP 9.6, REP 9.7
Figure
1.