REP 12.2 Finisher Control Board
Parts List on
PL 12.15 Item 2
Removal
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
1.
Separate the Finisher from the printer,
2.
Remove the left cover,
REP
12.1.
3.
Disconnect all connections to the Control Board.
4.
Remove 5 screws (metal) that secure the board to the bracket,
Figure 1 Remove the Finisher Control Board
Revised
Phaser 4600/4620/4622 Printer Service Manual
WARNING
GP
14.
Figure
1.
REP 12.3 Finisher Stacker Full Sensor
Parts List on
PL 12.15 Item 3
Removal
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
1.
Separate the Finisher from the printer,
2.
Remove the left cover,
REP
3.
Remove 4 screws (2 metal, 2 plastic) that secure the Control Board bracket to the Fin-
isher,
Figure
1.
Figure 1 Remove the Control Board bracket screw,
4.
Release the harness clamp and lift the front of the bracket,