17.3
Removing an XSCF DUAL Control
Cable
This section describes the procedure for removing an XSCF DUAL control cable.
Enable the removal of the XSCF DUAL control cables before attempting to remove
them. For details, see
Caution - Before you handle the XSCF DUAL control cables, wear a wrist strap to
ground any static electricity. If you perform this procedure without a wrist strap,
individual components or the overall system may be damaged. For details, see
Precautions on Static
1.
Remove the XSCF DUAL control cables from the SPARC M10-4S or the
crossbar box.
Pull out the XSCF DUAL control cable while pushing the lock release buttons (A
in the figure) on the both sides of the cable.
Note - The cables at the rear of the crossbar box are bundled together and fastened to the
right-hand cable support with a hook-and-loop fastener. To remove the XSCF DUAL control
cables, therefore, remove the hook-and-loop fastener from the cable support.
Figure 17-3     Removing the XSCF DUAL control cables (SPARC M10-4S)
"Chapter 7 Maintenance
Electricity."
Chapter 17 Maintaining the XSCF DUAL Control Cables
Flow."