System-stopped/hot removal (for an internal disk or PCIe card)
System-stopped/hot removal can be performed on an internal disk and a PCIe card.
Perform the following procedure to remove the unit.
Figure 7-28 System-stopped/hot removal flow (for an internal disk or PCIe card)
1. Open rack door
2. Switch mode switch
3. Check operating condition of system and
I/O device usage status
4. Stop system
5. Lower cable support for maintenance on
PCIe card
6. Remove target FRU
7. Secure cable support after maintenance on
PCIe card
8. Diagnose chassis requiring maintenance
9. Confirm that there is no problem with chassis
after removal
10. Return mode switch to original mode
11. Start system
12. Close rack door
192
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ June 2023
Removal complete