maintenance.
After replacing the FRU in step 7 in
(possible only in a system with a building block
1.
After completing maintenance of the target FRU, return to the replacefru
command operation of the XSCF firmware, and enter "f".
Please execute the following steps:
1) Confirm the XSCF STANDBY LED of BB#0 is not lit.
2) Turn off the breaker of BB#0.
3) Remove BB#0.
4) Execute either the following:
4-1) After the exchanged device is connected with the system,
turn on the breaker of BB#0, and please select 'finish'.
4-2) If you want to suspend the maintenance without exchanging device,
please select 'cancel'.
[f:finish|c:cancel] : f
Entering "f" displays the following screen. Wait until the processing has completed.
Waiting for BB#0 to enter install state.
[This operation may take up to 20 minute(s)]
(progress scale reported in seconds)
0..... 30..... 60..... 90..... 120..... 150..... 180..... 210.....
240..... 270..... 300..... 330..... 360..... done
 
Waiting for BB#0 to enter ready state.
[This operation may take up to 45 minute(s)]
(progress scale reported in seconds)
0..... 30..... 60..... 90..... 120..... 150..... 180..... 210.....
240..... 270..... 300..... done
 
Do you want to start to diagnose BB#0?[s:start|c:cancel] :
2.
After confirming that the FRU to be diagnosed is displayed, enter "s".
Do you want to start to diagnose BB#0?[s:start|c:cancel] : s
Note - If you are replacing the PCI Express card or internal disk, enter "c" to cancel the
SPARC M10-4S diagnosis. After finishing the steps described in this section, see
Diagnosing the system
with the -v, -p, or -s option specified.
After confirming again that the FRU to be diagnosed is displayed, enter "y".
3.
Diagnostic tests for BB#0 have started.
Initial diagnosis is about to start, Continue?[y|n] : y
"5.8.1 Releasing of the SPARC M10-4S chassis
board," and perform a diagnosis by executing the testsb command
configuration)," continue here.