Fujitsu M10-4 Service Manual page 56

Hide thumbs Also See for M10-4:
Table of Contents

Advertisement

Name properties of the PCI Express (PCIe) card
The following is an execution example of the showhardconf command.
XSCF> showhardconf -M
SPARC M10-4 ;
+ Serial:2081230012; Operator_Panel_Switch:Service;
+ System_Power:Off; System_Phase:Cabinet Power Off;
BB#00 Status:Normal; Role:Master; Ver:2209h; Serial:2081231002;
+ FRU-Part-Number:CA07361-D203 A2
+ Power_Supply_System:Single;
+ Memory_Size:512 GB;
CMUL Status:Normal; Ver:0301h; Serial:PP140601D9 ;
+ FRU-Part-Number:CA07361-D251 A4
+ Memory_Size:256 GB; Type: B ;
CPU#0 Status:Normal; Ver:4142h; Serial:00020203;
+ Freq:3.200 GHz; Type:0x20;
+ Core:16; Strand:2;
*1 Type: B is displayed for a CMU that has the SPARC64 X+ processor mounted. Type: A is displayed for a CMU
that has the SPARC64 X processor mounted.
*2 If the SPARC64 X+ processor is mounted, 3.200 GHz or 3.700 GHz; Type:0x20 is displayed. If the SPARC64 X
processor is mounted, 3.000 GHz; Type:0x10 is displayed.
*3 If the SPARC64 X+ (3.7 GHz (eight-core)) processor is mounted, "Core:8" is displayed.
Check the hardware RAID volume.
3.
To use the hardware RAID function installed in the SPARC M10-4/M10-4S to
check the configuration and status of the hardware RAID volume, log in to
Oracle Solaris on the control domain or root domain. Check the contents
displayed by the sas2ircu command of the SAS-2 Integrated RAID Configuration
Utility (referred to below as the SAS2IRCU utility).
Before performing hardware RAID volume maintenance, be sure to write down
the information on hardware RAID settings and the information on the
HDD/SSD components of the RAID volume.
For details on how to obtain the SAS2IRCU utility and the user guide, see
"Obtaining SAS-2 Integrated RAID Configuration Utility" in the latest version of
the Fujitsu M10/SPARC M10 Systems Product Notes.
The following is an example of what the sas2ircu command displays.
root# ./sas2ircu 0 display
LSI Corporation SAS2 IR Configuration Utility.
Version 19.00.00.00 (2014.03.17)
Copyright (c) 2008-2014 LSI Corporation. All rights reserved.
Read configuration has been initiated for controller 0
------------------------------------------------------------------------
Controller information
------------------------------------------------------------------------
Controller type
BIOS version
42
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ June 2023
(Omitted)
(*1)
/9999999
/9999999
(*1)
(*2)
(*3)
: SAS2308_2
: 0.00.00.00
;
;

Advertisement

Table of Contents
loading

This manual is also suitable for:

M10-4sSparc m10-4Sparc m10-4s