Restoring A Logical Domain To The Pre-Maintenance State - Fujitsu M10-4 Service Manual

Hide thumbs Also See for M10-4:
Table of Contents

Advertisement

If the system does not recognize the incorporated internal disk, make it
3.
recognized in the system.
a. Execute the cfgadm -c configure command to incorporate the target internal
# cfgadm -c configure <Ap_Id>
b. With the cfgadm -al command, check the status of the internal disk.
4.
If the CHECK LED on the mounted internal disk is not off, execute the cfgadm
-x command to turn off the CHECK LED on that internal disk.
# cfgadm -x led=fault,mode=off <Ap_Id>
5.
If you have enabled the hotplug service, execute the svcadm command to
disable the hotplug service.
# svcadm disable hotplug
Assign the I/O device of the incorporated internal disk to the logical domain.
6.
- If you have replaced a faulty internal disk, proceed to
- If you have added a new internal disk, perform operations according to the
6.5.3
Restoring a logical domain to the pre-maintenance
state
This section describes the flow of work in restoring a logical domain after FRU
maintenance to the pre-maintenance state. For details on the work and the
commands used, see "3.2 Operations and Commands Related to Logical Domain
Configurations" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain
Configuration Guide and the Oracle VM Server for SPARC Reference Manual for the
version you are using.
Note - If you have replaced the CPU memory unit lower in a system that has internal disks in
a hardware RAID configuration, you need to reactivate the hardware RAID volume. For
details, see "14.2.11 Re-enabling a Hardware RAID Volume" in the Fujitsu SPARC M12 and
Fujitsu M10/SPARC M10 System Operation and Administration Guide.
The following procedure returns a logical domain to the state in the ldm list-io
output results that were checked in step 4 in
of I/O
122
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ June 2023
disk into the logical domain.
logical domain to the pre-maintenance
descriptions in "14.2 Configuring Hardware RAID" in the Fujitsu SPARC M12
and Fujitsu M10/SPARC M10 System Operation and Administration Guide.
devices."
"6.5.3 Restoring a
state."
"5.3.2 Checking the assignment status

Advertisement

Table of Contents
loading

This manual is also suitable for:

M10-4sSparc m10-4Sparc m10-4s

Table of Contents