Operation Mode Settings - Formax FD 3200 Instruction Manual

Tabletop air feed folder
Table of Contents

Advertisement

Chapter 3 Advanced Operation
7-7.

Operation mode settings

The operation mode setting is used to set the fold stopper function of the folding plates 1 and 2 when the
power is turned on.
The following modes can be set.
Normal mode
[Normal] : When the power is turned on, use the normal mode to start up in the normal setting state.
Refold mode
[Last Fold] : When the power is turned on, this machine starts up in the setting state used last.
However the machine starts up with [Interval Setting] set to [OFF] and [Detect OFF] to [ON].
The adjustment values of the folding plates 1 and 2 return to default values if they are not
registered.
Folding stopper ixed mode
[Stopper Fixed] : Use [Stopper Fixed] to delete the setting operation on the control panel when folding
paper always in the same conditions. In this mode, when the power is turned on, this
machine is always set to the same conditions automatically, and initial operation of
the folding plates will not be performed. As the [Stopper Fixed] is automatically set to
the same conditions, the folding mode and paper size cannot be changed.
However the machine starts up with [Interval Setting] set to [OFF] and [Detect OFF] to
[ON]. The adjustment values of the folding plates 1 and 2 return to default values if
they are not registered.
1
Press the menu key to display [Other
Setting].
2
Select [Oper Mode] with the
3
Press the
key.
The [Oper Mode] screen is displayed.
4
Press the
key.
At this stage the mode can be changed to
[Normal], [Last Fold], or [Stopper Fixed]
5
Select a mode with the
6
Press the
key.
The selected details are set.
7
Press the
key.
Returns to [Other Setting].
3-26
or
key.
or
key.
Other Setting1/5
Feed Interval
Stack Roll Adj
Belt Convey Vol
Other Setting2/5
Oper Mode
Test Feed Set
Power Save Set
Oper Mode
Normal
Oper Mode
Last Fold