Formax FD 3200 Instruction Manual page 43

Tabletop air feed folder
Table of Contents

Advertisement

The folding stopper moves by 0.1 mm/0.004 inch every time the stopper adjustment key is pressed. While
holding down the stopper adjustment key, the value will continue to increase/decrease within the setting
range.
The value adjusted with the stopper
adjustment key will be displayed on the top
right section of the LCD display.
Example of operation procedures of single folding with
folded plane A longer by 1 mm/0.03 inch shown in the igure.
1
Press the stopper adjustment key of the
folding plate 1.
The numerical value can be changed at this
stage.
2
Press the
key to set the value to [+0.5].
3
Press the
key.
The changed value is set.
The changed value will be cleared by turning of the power switch. For registration of the changed
value, refer to "Registering the adjusted value" (p.3-6).
The numerical value of the folding plate can be changed by inputting the numerical value on the
keypad.
Inputting plus numerical value
Inputting minus numerical value
Folding plate 1
-
: Input the numerical value to be changed on the keypad.
: Change the display to minus with the
the numerical value to be changed on the keypad.
Chapter 3 Advanced Operation
Folding plate 2
+0.0/
+0.0/+0.0
+
+
A
Ejection direction
+0.0/
-
+0.5/
-
key and input
-
+
+
3-5

Advertisement

Table of Contents
loading