9-15. Operation mode when turned on

Set the state of the following functions when the power is turned on.
• Operation mode
• Double-feed detection
• Interval
• Processing speed
1
Touch the
On].
The [When Turned On] screen is displayed.
No.
Name
[1]
Oper Mode
[2]
D-Feed
key on the top screen —> Touch the
[5]
Set the movement of the folding stopper for the folding plates 1
and 2.
[Normal]: When the power is turned on, the machine starts up in
the state specified on the [Initial Screen] screen.
[Last Fold]: When the power is turned on, the machine starts up
with the settings and the counter of the last time the machine
was used in effect. However, [Detection] starts up set as turned
on, and the adjustment value of the folding plates 1 and 2 return
to the initial value when not saved.
After setting, an icon (
display section.
[Stopper Fixed]: The settings of the control panel can be omitted
when folding is always performed in the same conditions.
When [Stopper Fixed] set to on, the machine starts up in the
following states.
• The machine is always automatically set to the same conditions
when the power is turned on and initial operation of folding
plate is no longer performed.
• The folding mode or paper size cannot be changed on the [Basic
Settings] screen.
• [Standard Size] in [Detection] is automatically set to off.
• The adjustment value of the folding plates 1 and 2 returns to the
initial value when it is not saved.
• After setting, an icon (
display section.
Specify double-detection method (optical sensor or ultrasonic
sensor) when turned on with [Oper Mode] set to [Normal].
Chapter 3 Advanced Operation
key —> Touch [When Turned
Function
) is displayed on the touch panel
) is displayed on the touch panel
[1]
[2]
[3]
[4]
Default
value
Normal
Off
77