Installation

(85.1cm)
33.50"
(20.3cm)
(40.9cm)
8.00"
16.12"
(17.1cm)
6.75"
(86.2cm)
33.95"
(55.2cm)
21.75"
(24.3cm)
9.55"
12

Mounting the rack

SR12D and SR24D racks are wall-mounted.
SR48D racks are floor standing, but must be bolted to a wall for stability.
Note: Store unsecured racks where they cannot fall over and use caution to
keep racks stable during installation.

Wall mounted racks (SR12D and SR24D)

The wall must be strong enough to hold the racks. See Appendix A: Sensor
Delta specifications on page 32 for rack and module weights.
1. Use the mounting slot dimensions to mark the hole locations. You must
supply your own 3/8 inch (10mm) mounting hardware.
Note: The Control Electronic Module (CEM) on SR12D and SR24D racks is
located near the bottom of the rack. Install these racks at least 36
inches (1 meter) above the floor for easy access to rack controls.
2. Drill the holes and install the hardware.
3. Attach the rack to the wall.
SR24D rack
(61.3cm)
(81.6cm)
24.12"
32.12"
(114.8cm)
(20.3cm)
(40.9cm)
45.20"
8.00"
16.12"
(17.1cm)
6.75"
Figure 9: Sensor Delta rack wall mount hole diagrams
(85.1cm)
33.50"
(61.3cm)
(81.6cm)
24.12"
32.12"
(48.1cm)
18.93"
(32.6cm)
12.83"
(13.7cm)
5.38"
Electronic Theatre Controls, Inc.
SR12D rack
(64.8cm)
25.50"