ETC SR12D Installation Manual page 39

Sensor delta dimming system
Table of Contents

Advertisement

Sensor Delta Dimming Installation Guide
Connecting the last terminal on the network
To install the terminal at the end of a DMX512 or ETCLink network, follow the
instructions for connecting terminals from the previous page, except for the
following differences.
There should be one cable end and one wire in each slot on the plug-in
terminal.
The ETCLink network needs to have an ETCLink Terminator box (ETC part
number 7050A1024) installed in slot 1 and slot 2 of the plug-in terminal
Note: Connection polarity is not important when installing the Terminator
box.
ETCLink connector
ETCLink Data
Red–Slot 1
Black–Slot 2
1
2
3
4
5
ETCLink terminator
One lead in Slot 1,
Black–Slot 5, Red–Slot 6
the other in Slot 2
Note: If your lighting control console has a built-in ETCLink termination, you
should turn it off and use the termination on the end of your network
unless directed to do otherwise by an authorized ETC representative.
ETCLink
Common
6
7
8
Slot 7
Accessory wires
ETCLink connections
Black –
Slot 2
Red +
Slot 1
Common
Slot 7
16 AWG (1.5mm
2
)
Black; Slot 5
Red: Slot 6
wires
Figure 46: Connecting the last terminal on the network
DMX512 connector
8
7
6
5
DMX512 data
(–) Black – Slot 2
(+) Red – Slot 3
Table 9: Wall terminal wire connections
DMX connections
Black –
Red +
Shield
4
3
2
1
DMX512 Common
Slot 1
Slot 2
Slot 3
Slot 1
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sr24dSr48d

Table of Contents