ETC SR12D Installation Manual page 38

Sensor delta dimming system
Table of Contents

Advertisement

ETCLink connector
1
ETCLink plug numbers are on bottom
ETCLink connector
ETCLink Data
Red–Slot 1
Black–Slot 2
38
Connecting terminals to the network cable
ETCLink
PUSH
2
3
4
5
6
7
8
Male RJ5 socket
Both DMX512 and ETCLink terminals connect to the network with eight pin
terminal plugs. These plugs can be removed to make connecting wires easier.
Connecting terminals between the dimmer rack and the end of the network cable
1. Cut the network cable, leaving 10-12 inches (25-30cm) extra at both ends.
2. Follow the instructions in Preparing data cables for network connection
on page 18 to prepare both ends of the network cable.
3. Connect the wires to the terminal using the figure below. Because these
terminals are not at the end of the network there should be two wires
connecting to each slot. These connections are not terminated.
ETCLink
Common
1
2
3
4
5
6
7
8
Slot 7
Accessory wires
Black–Slot 5, Red–Slot 6
4. Install the wallplate on the backbox using the included faceplate screws.
DMX512 numbers are on top
Figure 44: DMX512 and ETCLink wallplate terminals
Data - (Black) – Slot 2
Table 8: Wall terminal wire connections
ETCLink connections
Black –
Slot 2
Red +
Slot 1
Common
Slot 7
Black; Slot 5
16 AWG (1.5mm
2
)
Red: Slot 6
wires
Figure 45: DMX512 and ETCLink terminal connections
DMX512 connector
8
7
6
5
4
3
2
1
Female RJ5 socket
DMX512 connector
8
7
6
5
4
3
2
1
DMX512 data
Data + (Red) – Slot 3
DMX connections
Black –
Red +
Shield
Electronic Theatre Controls, Inc.
DATA INPUT
DMX512
Common
Slot 1
Slot 2
Slot 3
Slot 1