Wellness Cocoon Fitness Pod Owner's Manual page 53

Table of Contents

Advertisement

Tools/Supplies Required:
1. Phillips screwdriver
2. Two adjustable pliers or wrenches
3. Ruler or tape measure
Heat Sensor connector is attached to rear of display panel. Sensing unit is located inside sauna
chamber (above wooden handle, near air shower holes), as shown in Figure 7.19.3 Harness
Location from Display/Control Panel and Figure 7.22.1 Heat Sensor Location Inside the Hood.
Carefully measure and write down length sensing unit extends through mounting nut into the
sauna chamber. When replacement sensor is installed, sensor should initially extend the same
distance into sauna chamber. Sensor may be moved further into chamber or closer to strain relief
nut as determined by temperature test.
Preliminary Procedures: Remove display/control panel (See Section 7.19)
Heat Sensor Removal Steps:
1. Disconnect heat sensor assembly cable from time/temp controller.
2. Carefully loosen Strain Relief Collar as shown in Figure 7.22.1 Heat sensor Location inside the
Hood by hand or with wrench, if necessary, until Sensor can be removed from Strain Relief nut
by pulling back into display panel area.
BE FIT• BE HEALTHY • BE WELL| 1 800 445-8418 | www.wellness-usa.com
Figure 7.22.1 Heat Sensor Location inside the Hood.