and lock in place. (NOTE: if it does not lock in place it can cause internal arching or
failure of heater operation).
C.
If connection is correct, turn power ON, select and start program. If heat does not
come on in 1-2 minutes, go to next step.
D.
Verify power and viability of heater and circuit using volt/ohm meter.
1. Disconnect heater harness from base.
CAUTION: High Voltage in this area.
2. Check across male pins (numbers 1, 2, 5 and 6) of connector for reading of 10 to
13 ohms to validate circuitry of heater core. If no Ohms reading, heater core may
be bad. Replace main heater assembly. If ohms OK, go to next step.
3. With heater still disconnected, select and start a program.
CAUTION: High Voltage in this area.
Carefully check for voltage across female pins of heater connector as follows:

6.2 Bed Vibration Massage Motors

The vibration massage motors in your unit are powerful and can be adjusted to low, mild, strong,
intense and maximum vibration. When the motors are run continuously on the two highest settings
(intense/maximum) for 40+ minutes, we recommend a short cool down period between sessions.
Our motors have a temperature sensor that will automatically temporarily shut down the motors
for 5 – 7 minutes when they are used continuously at highest settings (for approximately 45 – 60
minutes straight) to avoid overheating. As a general rule, we recommend allowing a 5 – 7 minute
rest and cool down period every hour of use.
BE FIT• BE HEALTHY • BE WELL| 1 800 445-8418 | www.wellness-usa.com
a. Pins 1 & 2
b. Pins 3 & 4
c. Pins 5 & 6
110/120 Volts
110/120 Volts
110/120 Volts