Face Air Vent(s) Replacement Steps:
Note:
The louver insert of the face air vent is generally the only part which needs to be
replaced. To replace the louver insert, follow these steps:
1. Using screwdriver, carefully pry louver insert away from the mounting ring as shown in Figure
7.16.1 Removing Face Air Vent(s).
2. Replace louver insert with new part and snap into place.
Note:
If mounting ring appears to be damaged, follow these steps:
1. Remove louver insert as described above.
2. Remove two (2) screws from face of mounting ring.
3. Remove mounting ring.
4. Replace with new part and reverse above steps to install.

7.12 Replacing Face Fan Assembly

Precautions: Be sure to turn unit OFF at main switch AND disconnect from power source before
going any further with this procedure.
Tools Required: Phillips screwdriver
Face Fan Assembly Removal Steps:
1. Remove the salt brick from its bracket.
2. Remove four (4) screws affixing grill and face fan assembly to unit as shown in Figure 7.17.2
Face Fan Grill.
3. Carefully pull face fan assembly out of unit as shown in Figure 7.17.4 Inserting/Removing Face
Fan Assembly.
BE FIT• BE HEALTHY • BE WELL| 1 800 445-8418 | www.wellness-usa.com