7.9 Replacing Vibration Motor(s)

Precautions:
Turn OFF main power switch located under contour bed on top of power box or disconnect the
unit from power source before beginning this procedure.
Tools/Supplies Required:
1. Phillips screwdriver
2. ½ inch socket wrench
3. Heat gun (or other heat source)
4. Loctite Removable Threadlocker (service removable)
Preliminary Steps:
1. Remove bed assembly from lower chassis (See Section 7.7).
2. Place bed upside down on soft, clean work surface.
3. Remove screws from motor guard. Set screws and guard aside.
Vibration Motor Removal Steps:
1. Remove screws from wire supports connected to cord of vibration motor(s) being replaced as
shown in Figure 7.9.1 Screws on Wire Connected to Vibration Motor.
2. Release bed support cup(s) housing the vibration control rheostats by removing mounting
screws as shown in Figure 7.9.2 Bed Support Cup.
3. Use wrench to remove mounting bolts of vibration motor as shown in Figure 7.9.4 Removing
Flange Bolt Attaching Motors. NOTE: Motor mounting bolts have been secured with Loctite
thread locking compound. Slight heating of these bolts may aid in loosening them for removal.
4. Remove all strain reliefs from the vibration assembly power cord for use in new assembly
installation.
Figure 7.9.1 Screws on Wire Connected
to Vibration Motors.