32.3

Area Option, User #

• Address: See Table 16
• Default:
• User 1: 15 (Assigned to Areas 1-4)
• User 2: 1 (Assigned to Area 1)
• User 3: 1 (Assigned to Area 1)
• Users 4-32: 0 (Not assigned to an Area)
• Selections: 0-15
User Area Options
Not Assigned to an Area
Assigned to Area 1
Assigned to Area 2
Assigned to Area 3
Assigned to Area 4
32.3.1
Parameter Description
Assigning PINs to multiple areas allows users to view and operate multiple areas from a single keypad.

33.0 Keypads

Wired Keypads 1 to 8 are fixed at Data Bus Addresses 1 to 8.
All keypads (and other Data Bus devices) are fully supervised. Supervision reports (missing, tamper, etc.) follow the System
Status Report routing.
The settings listed in this column are the Address jumper pins that must be covered by a jumper plug. See Section 10.1
Keypad Addressing on page 11 for more information.
* Address 0 is reserved for the installer's keypad. This keypad is not intended for permanent installation and should remain on-
premises for future programming sessions.
Page 78 P/N: 4998122677Cr1
PART III: PANEL PROGRAMMING
Keypad Address Pins
Keypad
1
2
Address
0*
OFF
OFF
ON
1
OFF
ON
2
OFF
ON
ON
3
4
OFF
OFF
ON
5
OFF
ON
6
OFF
ON
ON
7
8
OFF
OFF

Table 18: Keypad Data Bus Addresses

Copyright © 2003 Bosch Security Systems
Enter This Data Digit to Select Options
0
1
2
3
4
5
6
• •
• •
• •
• •
• • • •
• • • •
• • • • • • • •
4
8
16
MODE
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
7
8
9 10 11 12 13 14 15
• •
• •
• •
• •
• • • •
• • • •
• • • • • • • •
• • • • • • • • • • • • • • • •