30.12 Authority Level Option 12: Extend Auto On Time
• Address: 0375
• Default: See table below
• Selections: 0-15
Authority Level Configuration 12 Options
No PIN Required
Assign to Authority Level 1
Assign to Authority Level 2
Assign to Authority Level 3
Assign to Authority Level 4
30.12.1 Parameter Description
This parameter enables/restricts the Extend Auto On Time function ([#] + [5] + [1]) by Authority Level.
The Extend Auto On Time function delays the auto-on time by one hour if entered during the Auto On Pre-Alert Time.
See the DS7240-UK User's Guide (P/N: 4998122088) and "Auto On Pre-Alert Time" on page 43 for more information.

30.13 Authority Level Option 13

• Address: 0376
• Default: See table below
• Selections: 0-15
Authority Level Configuration 13 Options
No PIN Required
Assign to Authority Level 1
Assign to Authority Level 2
Assign to Authority Level 3
Assign to Authority Level 4
30.13.1 Parameter Description
This parameter enables/restricts the following functions by Authority Level:
• Adjust keypad sounder volume and lighting ([#] + [4] + [9])
• Change or reset outputs ([#] + [5] + [4])
• Chime toggle Off/On ([#] + [6] + [1])
• Auto-Forward – Enable/Disable ([#] + [8] + [2])
DS7240-UK Reference Guide
0
• •
0
• •
Copyright © 2003 Bosch Security Systems
Enter This Data Digit to Select Options
1
2
3
4
5
6
7
8
• •
• •
• •
• •
• •
• •
• • • •
• • • • • • • •
• • • • • • • • • • • • • • • •
Enter This Data Digit to Select Options
1
2
3
4
5
6
7
8
• •
• •
• •
• •
• •
• •
• • • •
• • • • • • • •
• • • • • • • • • • • • • • • •
9 10 11 12 13 14 15
• •
• •
• •
• •
• • • •
• • • •
• • • • • • • •
9 10 11 12 13 14 15
• •
• •
• •
• •
• • • •
• • • •
• • • • • • • •