Conettix Universal Dual Path Communicator
Selections: Up to sixty-three characters (letters, numbers, and dashes)
The hostname identifies the B465 on the network. Leave this parameter blank to use the
factory default hostname, or enter a custom hostname.
Notice!
Leave this parameter blank to use factory default hostname
The factory default hostname begins with the letter B, followed by the last six digits of the
modules MAC address.
Use the hostname on a local network using DHCP. To use the hostname externally, you must
enter the hostname in the DNS server.
You can use the hostname to connect to the B465 with RPS for configuration and diagnostics.
USB Menu Location
[3] Advanced Communication Configuration > [3] Ethernet Setup > [5] Module Hostname
7.10.15

TCP/UDP Port Number

Default: 7700
Selections: 1 - 65535
For IP communications with RPS, in typical installations, keep the port number at the default.
USB Menu Location
[3] Advanced Communication Configuration > [3] Ethernet Setup > [6] TCP/UDP Port Number
7.11

Cellular Setup / Cellular Plug-in Module

Use the parameters in this section to configure the B465 for the cellular plug-in communicator
module.
7.11.1

Network Access Point Name (APN)

Default: EAAA.BOSCH.VZWENTP
Selections: 0-99, A-Z, a-z, - , : , .
This parameter sets the network access point name (APN). Enter up to 99 characters. The
field is case sensitive.
Notice!
The default APN, EAAA.BOSCH.VZWENTP, is new
The previous default, wyless.apn, is still valid. There is no need to change the APN for existing
accounts.
USB Menu Location
[3] Advanced Communication Configuration > [4] Cellular Setup > [1] Cellular Plug-in Module
> [1] Network Access Point Name (APN)
7.11.2

Network Access Point User Name

Default: Blank
Selections: 0-30 ASCII characters
Enter up to 30 ASCII characters for the Network Access Point user name.
The user name is case sensitive.
USB Menu Location
[3] Advanced Communication Configuration > [4] Cellular Setup > [1] Cellular Plug-in Module
> [2] Network Access Point User Name
7.11.3

Network Access Point Password

Default: Blank