Swinger Count For Alarm Output; Swinger Count For Zone Reports - Bosch DS7240-UK Reference Manual

Control/communicator
Table of Contents

Advertisement

37.4

Swinger Count for Alarm Output

• Address: 1029
• Default: 3
• Selections:
• 0 (Swinger disabled)
• 1-15
37.4.1
Parameter Description
Each individual zone has a swinger count for alarm output.
Swinger Shunt reports are not sent for Swinger Shunt for Alarm Output. Swinger Shunt reports have their own swinger count
(see Section 37.5 Swinger Count for Zone Reports on page 104). The Swinger Count is reset on both arming and disarming of
the system, allowing the Swinger Shunt feature to work for both non-24-hour and 24-hour zones. A trouble condition occurs
after Swinger Shunt.
Example: Assume the Swinger Shunt option is enabled, the panel is armed, no zones are in alarm and the Swinger Count for
Alarm Output is set to 2. Zones 1, 3 and 5 go into alarm. At the end of Bell Time, the Swinger Count for Alarm Output for
Zones 1,3 and 5 decrements from 2 to 1. Since the counter does not reach zero, no zones are bypassed. A second alarm
event for any of those zones bypasses that zone.
When the Swinger Count is set to zero (0), the Swinger Count for Alarm Outputs feature is disabled. The alarm
outputs activate on every new alarm.
37.5

Swinger Count for Zone Reports

• Address: 1030
• Default: 0
• Selections:
• 0 (Swinger disabled)
• 1-15
37.5.1
Parameter Description
This parameter sets the swinger count for zone alarm, trouble, and restoral reports.
Swinger shut down for the dialer is a global function that affects all zones.
Swinger Shunt [33] reports are sent for Swinger Shunt of zones.
The Swinger Count is reset on both arming and disarming, allowing the Swinger Shunt feature to work for both non-24-hour
and 24-hour zones.
Example: Assume the Swinger Shunt option is enabled, the panel is armed and there are no alarms. When the zone sends an
Alarm or Trouble event to the dialer, the swinger count for zone reports is checked. If the counter is at zero, the zone is
already Swinger Shunted and no report is sent. If the counter is not at zero, the panel decrements the counter. If the counter
then goes to zero after the report is sent, the Swinger Shunt [33] report is sent. The zone is then swinger shunted.
If the swinger count is set to zero (0), the Swinger Count for Zone Reports feature is disabled. The dialer sends all alarm or
trouble events.
Page 104 P/N: 4998122677Cr1
PART III: PANEL PROGRAMMING
Copyright © 2003 Bosch Security Systems
DS7240-UK Reference Guide