39.3

Mode (Steady, Pulse, One Shot), Output ##

• Address: See Table 26
• Default: See Table 26
• Selections: 0-13 (see Table 28)
39.3.1
Parameter Description
There are two types of outputs: state-driven outputs and event-driven outputs. State-driven outputs follow the state of a
condition, either on or off. For example, a state-driven output is Type 0,1 Armed. The output is active when the panel is armed
and inactive when the panel is disarmed.
Event-driven outputs follow events when they occur. These events have no On or Off state. For example, an event-driven
output is Type 2,0 [P] key on a RF Keyfob. When the key is pressed, the output is activated.
The following table describes the mode operation for both on-board and off-board outputs.
Mode
Mode Type
Output
Type
1
Steady
State
Event
2
Latch
State
Event
3
Toggle
State
Event
4
Pulse
State
Event
5
One-Shot
State
Event
6
One-Shot
State
with Re-
Trigger
Event
7
One-Shot
State
with Reset
Event
8
Steady,
State
Reversed
Event
Logic Normal
9
Latch,
State
Reversed
Event
Logic Normal
10
Pulse,
State
Reversed
Event
Logic Normal
One-Shot,
11
State
Reversed
Logic Normal
Event
12
One-Shot
State
with Re-
Trigger,
Event
Reversed
Logic Normal
13
One-Shot
State
with Reset,
Reversed
Event
Logic Normal
DS7240-UK Reference Guide
Output turns on when the condition is active and turns off when the condition is inactive.
Output turns on when the event occurs. [System Reset] turns the output off.
Output turns on when the condition is active and remains on until [System Reset] is pressed.
Output turns on when the event occurs and remains on until [System Reset] is pressed.
When the condition goes from inactive to active, the output changes state. The condition going from active to
inactive has no effect.
Whenever the event occurs, the output changes state.
When the condition is active, the output pulses. When the condition is inactive, the output is off.
When the event occurs, the output pulses. The output remains pulsing until [System Reset] is pressed.
When the condition changes from inactive to active, the output turns on. The output turns off at the end of the
One-Shot time. Once the output is on, any changes in the condition are ignored.
When the event occurs, the output turns on and remains on for the One-Shot time. A second event does not affect
the output.
When the condition changes from inactive to active, the output turns on and remains on for the One-Shot time. If
the condition goes inactive and active again, the One-Shot time is restarted and the output remains on.
When the event occurs, the output turns on and remains on for the One-Shot time. If a new event occurs, the One-
Shot time is restarted and the output remains on.
When the condition changes from inactive to active, the output turns on and remains on for the One-Shot time. If
the condition goes inactive, the output is turned off early.
When the event occurs, the output turns on and remains on for the One-Shot time. [System Reset] turns the
output off early.
Output turns on when the condition is inactive and turns off when the condition is active.
Output turns off when the event occurs. [System Reset] turns the output on.
Output turns on when the condition is inactive and remains on until [System Reset] is pressed.
Output turns off when the event occurs and remains off until [System Reset] is pressed.
When the condition is inactive, the output pulses. When the condition is active, the output is off.
When the event occurs, the output is off. The output remains off until [System Reset] is pressed.
When the condition changes from active to inactive, the output turns on. The output turns off at the end of the
One-Shot time. Once the output is on, any changes in the condition are ignored.
When the event occurs, the output turns off and remains off for the One-Shot time. A second event does not affect
the output.
When the condition changes from active to inactive, the output turns on and remains on for the One-Shot time. If
the condition goes active and inactive again, the One-Shot time is restarted and the output remains on.
When the event occurs, the output turns off and remains off for the One-Shot time. If a new event occurs, the One-
Shot time is restarted and the output remains off.
When the condition changes from active to inactive, the output turns on and remains on for the One-Shot time. If
the condition goes active, the output is turned off early.
When the event occurs, the output turns off and remains off for the One-Shot time. [System Reset] turns the
output on early.

Table 28: Output Mode Options

Copyright © 2003 Bosch Security Systems
Operational Description
PART III: PANEL PROGRAMMING
P/N: 4998122677Cr1 Page 115