28.5

Opening/Closing Report Routing

• Address: 0262
• Default: See table below
• Selections: 0-5
Data Digit Entry
Default
28.5.1
Parameter Description
This is a global parameter that affects all zones, all areas and all PINs.
The Exit Error [18] and Recent Closing [19 – 20] reports follow alarm routing. See Section 56.0 Dialing Attempt Tables on
page 146 for the dialing sequence and a description of a Comm Fail event.
You must enable reporting at the Global Reporting Options prompt (page 38) and enter at least one phone number
for one routing destination (page 32).
28.6

Exit Time Restart

• Address: 0263
• Default: 0 (No Exit Time Restart)
• Selections:
• 0 = No Exit Time Restart
• 1 = Exit Time Restart
28.6.1
Parameter Description
If this parameter is set to Restart (1), a violation, restoral, second violation of an Entry/Exit zone (before the end of Exit Delay)
restarts Exit Delay. One restart is allowed per arming cycle. Violation, restoral, second violation must all occur at the same
Entry/Exit zone.
Page 58 P/N: 4998122677Cr1
PART III: PANEL PROGRAMMING
0
No Reports, no Events to Log/Printer
1
Reports to Destination 1, Events to Log/Printer
2
Reports to Destination 2, Events to Log/Printer
3
Reports to Destinations 1 & 2, Events to Log/Printer
4
Reports to Destination 2 only on Destination 1 Comm Fail Event, Events to Log/Printer
5
No reports, Events to Log/Printer
Copyright © 2003 Bosch Security Systems
Option
DS7240-UK Reference Guide