28.2

Arming Options 2

• Address: 0259
• Default: See table below
• Selections: 0-15
Arming Options 2
No Options Enabled
First Area to Open/Last Area to Close Reporting
Make Area 1 Common Area
Enable All Areas All On ([#]+[8]+[0])
Enable All Areas All Off ([#]+[8]+[1])
28.2.1
Parameter Options
• First Area to Open [164]/Last Area to Close [165] Reporting: The system transmits one Closing [165] report when all
areas are turned On and one Opening [164] report when any area is turned Off.
• User PIN Authority Level must be enabled, and Opening/Closing reports must be enabled for all areas.
• Open and Close reports are for Area 1 using Area 1's account numbers.
All area account numbers must be the same in order to send Area 1's Account Numbers. See Section 29.0 Areas
on page 62 for information on programming account numbers.
Enabling the "Restrict Open/Close Reports" feature overrides the "First Area to Open/Last Area to Close
Reporting" feature. See Section 29.2 Area # Opening [89-96]/Closing [42-67] Reporting Options on page 63 for
more information regarding the "Restrict Open/Close Reports" feature.
• All On, and Area 1 disarms when any other area is disarmed.
• Enable All Areas All On Function ([#] + [8] + [0])*: Faulted zones are force-armed.
• Enable All Areas Off Function ([#] + [8] + [1])*: This function always requires a passcode.
* All = All areas in which the user has the appropriate authority level.
28.3

Bypass/Force Arm Limit

• Address: 0260
• Default: 7
• Selections: 0-15
28.3.1
Parameter Description
The parameter configures all areas.
This parameter sets the maximum number of zones that can be force-armed or bypassed for any one area. The area will not
arm if this limit is reached and zones remain faulted.
Entering zero (0) allows an unlimited number of zones to be force-armed or bypassed.
The Zone Function determines which zones are bypassable.
Page 56 P/N: 4998122677Cr1
PART III: PANEL PROGRAMMING
0
• •
Copyright © 2003 Bosch Security Systems
Enter This Data Digit to Select Options
1
2
3
4
5
6
7
8
• •
• •
• •
• •
• • • •
• • • •
• • • • • • • •
• • • • • • • • • • • • • • • •
9 10 11 12 13 14 15
• •
• •
• •
• •
• • • •
• • • •
• • • • • • • •
DS7240-UK Reference Guide