Bell Time; Siren Warble Frequency; Siren Output Volume - Bosch DS7240-UK Reference Manual

Control/communicator
Table of Contents

Advertisement

38.2

Bell Time

• Address: 1040
• Default: 10
• Selections: 0-15 (1-minute increments)
38.2.1
Parameter Description
Bell Time determines how long, 0 to 15 minutes, the Alarm Output, Fire Alarm Output and Silent Alarm Output functions
remain activated when triggered by an alarm event.
38.3

Siren Warble Frequency

• Address: 1041
• Default: 7
• Selections: 0 (lowest tone/frequency) to 15 (highest tone/frequency)
38.3.1
Parameter Description
This parameter sets the siren warble frequency for non-fire alarm output functions.
Programmable Output 2 (PO 2) can be configured as a supervised horn/speaker output (see Section 38.1 Global Output
Options on page 107).
This parameter sets the warble frequency for the alarm output functions (1-8, 1-9, 1-10). The setting chosen here does not
apply to other output functions.
Lowering the frequency effectively raises the perceived volume.
38.4

Siren Output Volume

• Address: 1042
• Default: 7
• Selections: 0 (no sound) to 15 (loudest); 1 = quiet)
38.4.1
Parameter Description
PO 2 can be configured as a supervised horn/speaker output (see Section 38.1 Global Output Options on page 107).
This parameter sets the perceived volume for the Alarm Output Arming Beep and when the output is on Steady.
Page 108 P/N: 4998122677Cr1
PART III: PANEL PROGRAMMING
Copyright © 2003 Bosch Security Systems
DS7240-UK Reference Guide