Bosch DS7240-UK Reference Manual page 114

Control/communicator
Table of Contents

Advertisement

Function Type
Digit
Digit
1
2
2
13
Ready to Arm (No zones
faulted)
2
14
Exit Error/Bad Set
2
15
AC 60 Hz
3
0
Ground Start
3
1
Follow Zone Function 1
To
3
15
Follow Zone Function 15
4
0
Change Outputs
4
1
Alarm Zone Function 1
To
4
15
Alarm Zone Function 15
5
0
Change Outputs
5
1
Trouble Zone Function 1
To
5
15
Trouble Zone Function 15
6
0
Change Outputs
6
1
Follow PIN 1
To
6
15
Follow PIN 15
7
0
Follow PIN 16
To
7
15
Follow PIN 31
8
0
Follow PIN 32
8
1
Sked Only
8
2
Change Outputs
8
3
Always On
8
4
Confirmed Alarm
8
5
Unconfirmed Alarm
8
6
Tamper
8
7
Bypass
8
8
Enhanced Siren
8
9
Alarm Abort
8
10
RF Transmitter Missing
8
11
RF Transmitter Low Battery
8
12
RF Receiver Jamming
8
13
Fire Alarm Only
8
14
Personal Alarm
Page 114 P/N: 4998122677Cr1
PART III: PANEL PROGRAMMING
Output is activated (on) when: (1) panel is disarmed & no zones are faulted (2) panel is armed & no
zones are faulted (3) panel is armed & any zone is faulted. Output is deactivated (off) when panel is
disarmed & any zone is faulted. Output is deactivated even if the zone became faulted when panel
was armed.
Activates if zone is faulted at the end of Exit Delay or if a Bad Set condition occurs. Resets when the
system is disarmed.
Activates on 60 Hz. Resets on 50 Hz.
Activates for approximately 0.5 seconds at the start of any dialing attempt. Use to bring up dial tone in
ground start phone systems.
These 15 output functions activate for any fault on any zone assigned to the specified Zone Function.
Activated/deactivated by Change Outputs function ([#] + [5] + [4]).
These 15 output functions activate for alarms on any zone assigned to the specified Zone Function
and the area(s) the output is assigned to. They reset when none of the zones assigned to the
specified Zone Function are in alarm.
Activated/deactivated by Change Outputs function ([#] + [5] + [4]).
These 15 output functions activate for troubles on any zone assigned to the specified Zone Function.
They reset when none of the zones assigned to the specified Zone Function are in trouble.
Activated/deactivated by Change Outputs function ([#] + [5] + [4]).
These output functions activate when the specified PIN is entered.
Output Function Type 7, 12 follows User 28, which can be programmed as the Guard Code User.
See Section 34.8 Guard Code Options on page 85 for more information.
These output types are event-driven. See Section 39.3 on page 115 for more information.
PIN area assignments are ignored when these output functions are selected.
This output type is only available for Outputs 1 to 15. Activated by Skeds. See Section 40.2 Assign
(Area or Output), Sked # on page 118 for more information.
Activated/deactivated by Change Outputs function ([#] + [5] + [4]).
Output is always activated.
Activates when the requirements for a confirmed alarm are met. Resets when the confirmed alarm is
reset by the installer.
Activates on any non-24-hr alarm, 24-hr tamper, 24-hr emergency, or 24-hr burglary alarm. Resets
when the confirmation alarm timer resets or when a PIN is entered.
Activates on any tamper condition. Resets when tamper condition is restored and when Installer PIN
is entered and [System Reset] key is pressed.
Activates when any input is bypassed. Resets when all input bypasses are cleared.
Activates on Exit Delay, Entry Delay, Chime, Alarm, Tamper, or Bad Set. Resets at the end of bell
time or when a PIN is entered.
Activates on a cancelled alarm. Resets when alarm is cleared.
Activates when any RF transmitter is missing.
Activates when any RF transmitter is reporting a low battery.
Activates when RF Jamming is present for 5 minutes.
Activates on Fire Alarm only. Follows Bell Time. PIN resets. Does not pulse in Temporal Code 3
format.
Activates when one of its assigned areas is set to Personal Alarm. Resets by entering a valid user
PIN, pressing the [System Reset] key, or by DSRPS (System Reset command). Activates on any of
the following conditions: (1) If a Duress User PIN is entered (2) If an Emergency key is active in an
area and "Activate Panic Alarm Response" and "Alarm Output" are enabled for the key (3) If a RF
keyfob reports a Panic alarm, or (4) If a zone configured for 24-hr Visible Panic (Zone Function Type
6) goes into alarm.
Table 27 (cont.): Output Function Types
Copyright © 2003 Bosch Security Systems
Description
DS7240-UK Reference Guide