Local Programming Options - Bosch DS7240-UK Reference Manual

Control/communicator
Table of Contents

Advertisement

27.2

Local Programming Options

• Address: 0257
• Default: See table below
• Selections: 0, 4, 8, 12
Local Programming Options
No Options Selected
Reserved
Reserved
Keypad Programming Enabled
PK32 (Programming Key) Enabled
27.2.1
Parameter Options
• Keypad Programming Enabled: All panel parameters can be programmed from any system text keypad or an Installer
Keypad. See Section 19.0 Installer Keypad on page 26 and Section 20.0 Installer Mode on page 26 for more information.
If Keypad Programming or PK32 are not enabled, access to the panel via a keypad will not be possible. Remote
programming (DSRPS-INT'L) will be the only programming method available.
• PK32 (Programming Key) Enabled: The PK32 Programming Key can be used to send or receive a program record (the
panel's parameter settings). See page 30 for more information regarding the Programming Key.
If the Keypad Programming and Remote Programming options (see Section 27.1 on page 53) are not enabled,
there will be no way to access panel programming.
Page 54 P/N: 4998122677Cr1
PART III: PANEL PROGRAMMING
0
• •
Copyright © 2003 Bosch Security Systems
Enter This Data Digit to Select Options
1
2
3
4
5
6
7
8
• •
• •
9 10 11
12
13 14 15
• •
• •
DS7240-UK Reference Guide