Flag F.
DSX Network Access
DSX-1 level I/O network side access is achieved through the 64-pin/50-pin amphenol
connectors for the access modules.

3.4 Loop Interfaces

Flag G. Loop Access
Loop side access is achieved via 64-pin/50-pin amphenol connectors for HDSL,
HDSL2, ISDN, T1, and DS1.

3.5 Test Access

Flag H. Loop Test Access
Six wire-wrap connections provide metallic loop testing access to the customer loops.
Flag I.
DSX-1 Test Access
Six wire-wrap connections provide digital loop testing access to the customer loops.

3.6 Management Interfaces

Flag J.
Network Management Port
DB-25 female connector allows port access for an X.25 connection.
Flag K. Administrative Port
Female DB-25 local access port to VT100 terminal, modem, or other serial device for
permanent provisioning and troubleshooting.
Flag L. RJ-45 for 10BaseT
RJ-45 jack provides for TCP/IP (Telnet, SNMP, TFTP) communication over 10BaseT.
Flag M. RS-485
Set of wire-wrap pins provides a bus for TL1 intershelf management. Up to 32
additional devices can be daisy-chained to the first shelf at a total distance of 4000
feet.

3.7 Alarms

Flag N. Audiovisual Alarms
The shelf provides for eight alarm outputs:
Critical Visual
Critical Audible
Major Visual
Major Audible
Minor Visual
Minor Audible
AUX 1