ADTRAN Total Access 3000 System Manual page 217

Hide thumbs Also See for Total Access 3000:
Table of Contents

Advertisement

Immediately inspect it for possible shipping damage. If the equipment has been
damaged in transit, file an immediate claim with the carrier and then contact ADTRAN
Customer Service.
1.3.2
Install the Primary OC-3 MUX
1. Slide the OC-3 MUX half-way into slot A of the system chassis. Connect the
Receive fiber to the lower SC connector and the Transmit fiber to the upper SC
connector. Thread the two fibers up along the faceplate and the two round
standoffs so that the fibers exit the MUX through the "notch" at the top of the
faceplate. Gently, but firmly push the module the rest of the way into the slot,
being careful not to pinch the fibers between the faceplate and the shelf. Push the
ejector tab up and against the faceplate. See DLP-719 for proper routing of fibers
through a heat baffle.
2. Allow the unit approximately 60 seconds to completely power up and synchronize
with the SCU. Upon completion, the POWER LED will be flashing yellow,
indicating an Out-of-Service, Unassigned (OOS-UA) state and the ONLINE LED
will be on. The Status and Optics LEDs will be red and the Clock LED will be
yellow.
3. If a single configuration is being employed, proceed to DLP-742 for procedure to
provision the OC-3 MUX module. If a protection configuration is being employed,
proceed with section 1.4, Protect MUX Installation Procedure, to install the Protect
MUX.
1.4
Protect MUX (slot B) Installation Procedure
1.4.1
Unpack and Inspect the Protect OC-3 MUX Module
Each OC-3 MUX Module is shipped in its own cardboard shipping carton. Open the
carton carefully and avoid deep penetration into the carton with sharp objects. After
removing the unit from the carton, unwrap the bubble-wrap and pull the unit from the
anti-static plastic bag.
Immediately inspect it for possible shipping damage. If the equipment has been
damaged in transit, file an immediate claim with the carrier and then contact ADTRAN
Customer Service. (See APX 901 - Warranty and Customer Service.)
1.4.2
Install the Protect OC-3 MUX
1. Slide the OC-3 MUX half-way into slot B of the system chassis. Connect the
Receive fiber to the lower SC connector and the Transmit fiber to the upper SC
connector. Thread the two fibers up along the faceplate and the two round
standoffs so that the fibers exit the MUX through the "notch" at the top of the
faceplate. Gently, but firmly push the module the rest of the way into the slot,
being careful not to pinch the fibers between the faceplate and the shelf. Push the
ejector tab up and against the faceplate. See DLP-719 for proper routing of fibers
through a heat baffle.
Total Access
®
3000/3010 System Manual
6TANTP506-1E
TOTAL ACCESS 3000/3010
© 2002, ADTRAN, Inc.
NTP-506
Page 3 of 4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Total access 3010

Table of Contents