ADTRAN Total Access 3000 System Manual page 379

Hide thumbs Also See for Total Access 3000:
Table of Contents

Advertisement

Perform Steps Below in the Order Listed
1.2.2
Configure the SCA Restore Options
1. From the System Configuration (SCA) menu, select SCA SCU Restore
Provisioning, and press <Enter>.
The SCA SCU Restore Provisioning menu allows the user to specify which types
of provisioning options are to be overwritten by the SCA restore and which types
of provisioning options will be unaffected. The following text provides a
description of the types of provisioning options available on the SCU.
able or enable the ability to overwrite provisioning options to the SCU using
the restore function. If the Restore Provisions To SCU option is enabled, the
remaining options described below will dictate what options are overwritten
and which are unaffected. If the Restore Provisions To SCU option is
disabled, no provisioning changes will be made to the SCU during an SCA
restore. This option is useful for protecting the current SCU settings during an
SCA restore operation that should only impact the Cell Switch and Access
Modules.
Restore SCU SCA Provisions – This option dictates whether SCA-related
provisioning parameters should be restored on the SCU. All SCA provisions
such as SCA AutoSave, filename, SCU and Access Module restore settings,
etc. will be overwritten if this option is set to enable. No SCA provisions will
be overwritten if this option is set to disable.
Restore SCU Network Provisions – This option dictates whether general IP
network-related provisioning parameters should be restored on the SCU.
General IP network-related parameters include the various telnet, DNS, IP-
forwarding, and firmware TFTP server settings. This option does not control
the restore of network interface settings (such as IP address, netmask or
gateway).
Restore SCU Network Interface Provisions – This option dictates whether
network interface related settings (such as IP address, netmask and gateway)
for the Ethernet, Inband, and Local PPP network interface are to be
overwritten on the SCU. If this option is enabled, the network interface
parameters will be overwritten by the SCA restore. If this option is disabled,
no changes will be made to the network interface parameters.
If the network interface parameters are changed, all TCP/IP, SNMP, and
Telnet communication will be halted until the devices trying to communicate
with the SCU are provisioned to correctly handle the change.