1.14.10 Connect to Craft Port of Host SCU and Verify that All Banks are
Visible on Menu
When all the Total Access 3000/3010 shelves are tested and provisioned as desired by
the user, all the shelves connected by the RS-485 bus should be visible from the Host
shelf. The following procedure verifies that all the shelves can be seen from the Host
SCU.
1. Determine which shelf in the chain is the Host. The host shelf can be identified by
the lit "HST" LED on the SCU.
2. Logon to the system of the Host shelf
3. From the Total Access Menu, select option 1, System Controller and press
<Enter>.
4. From the System Controller Menu, select option 2, Provisioning, and press
<Enter>.
5. From the Provisioning Menu, select option 1, General, and press <Enter>.
6. From the General Menu, select option 1, Management Ports, and press <Enter>.
7. From the Management Ports Menu, select option 1, Auxiliary Shelf Access, and
press <Enter>.
8. From the Auxiliary Shelf Access Menu, you will be able to see all of the shelves
visible to the Host.
9. Select a shelf number different from the host and press <Enter>. The next screen
will be the logon screen of the selected shelf.
10. To return to the Host Auxiliary Shelf Access Menu of the Host shelf, press
<Control> and <X> simultaneously.
11. Return to the Total Access Menu by pressing <Esc>.
12. From the Total Access Menu, select option 6, Logoff and press <Enter>.
13. To logoff at this time, at the Exit and Logoff screen press Y and <Enter>.
Pressing N and <Enter> at Step 13 above will return you to the Total Access
Menu.