1.1
Setting IP Parameters for an SCU
Perform Steps Below in the Order Listed
References to common, but differing, parameters between the Total Access
3000 and the Total Access 3010, such as number of slots, will be conveyed
by the convention a/b. The "a" represents the Total Access 3000 parameter
and the "b" represents the Total Access 3010 parameter. For example, the
differing number of access slots in the two platforms, 28 for the Total Access
3000 and 22 for the Total Access 3010, would be displayed "28/22."
1.1.1
Introduction
If the Total Access 3000/3010 shelf is to be connected to an IP network for Telnet,
TFTP, or SNMP management, there are several IP parameters that need to be set for
the shelf to communicate with the network. These parameters along with the
procedures for setting them, are described in this DLP.
1.1.2
Prerequisite Procedures
This procedure assumes that an SCU is installed in the Total Access 3000/3010 shelf.
1.1.3
Tools and Materials Required
• Data cable to connect to VT100 terminal or PC configured as a VT100 terminal
• VT100 or PC configured as a VT100 terminal
To prevent electrical shock, do not install equipment in a wet location or
during a lightning storm.
Electronic modules can be damaged by static electrical discharge. Before
handling modules, wear an antistatic discharge wrist strap to prevent damage
to electronic components. Place modules in antistatic packing material when
transporting or storing. When working on modules, always place them on an
approved antistatic mat that is electrically grounded.
Total Access
®
3000/3010 System Manual
TOTAL ACCESS 3000/3010
NOTE
WARNING
CAUTION
6TADLP718-1E
DLP-718
Page 1 of 4
© 2002, ADTRAN, Inc.