6TANTP505-1E
TOTAL ACCESS 3000/3010
NTP-505
Page 4 of 4
1.5
Placing the Units in Service
Ensure all alarms are cleared before placing the modules In-Service. This will
prevent false alarms from being transmitted to the network.
1. From the working MUX Menu, select option 2, Provisioning, and press <Enter>.
2. From the Provisioning Menu, select option 4, Service State, and press <Enter>.
3. From the Service State Menu, select option 1, In Service, and press <Enter>.
4. Repeat the above steps for the protect MUX.
At this point the POWER LED on both MUX modules will illuminate green,
indicating an In-Service state. Alarms will also be generated in this state.
MUX A ONLINE LED should be illuminated green and MUX B ONLINE
LED should be off. The STATUS LED on both MUX units should be greenif
an STS-1 signal is present and synchronized. If no STS-1 signal is present,
both LEDs will be illuminated red.
1.6
Follow-up Procedure
Please proceed to the appropriate NTP for the installation of the access modules to
be installed in the Total Access 3000/3010 chassis.
© 2003, ADTRAN, Inc.
NOTE
NOTE
Total Access
®
3000/3010 System Manual