6TADLP741-1E
TOTAL ACCESS 3000/3010
DLP-741
Page 4 of 8
Perform Steps Below in the Order Listed
4. Selecting option 5, Restore Factory Defaults, will restore the provisioning of the
unit to its factory default state. The factory default settings are listed below.
Line Build Out:
Clock Source:
Service State:
Linked Provisioning:
PM Threshold Enable:
VT Channel Mapping:
5. Return to the Primary MUX Main Menu by pressing <Esc> and proceed to the
next section.
1.4
Performance Monitoring Provisioning
Performance monitoring options can be set to enable the module to capture
performance monitoring data. Alarm thresholds for various alarm conditions are set
and, when exceeded, issue an appropriate alarm. To set alarm threshold values perform
the following:
1. From the Primary MUX Main Menu select option 6, Performance Monitoring, and
press <Enter>.
2. Options 5 through 8 are able to have alarm thresholds set. Options 5 and 6 will be
shown here. Options 7 and 8 are identical, except the alarm thresholds are based
on 15 minute intervals instead of 24 hour intervals. From the Performance
Monitoring Menu select option 5, STS1 Daily Thresholds, and press <Enter>.
1.
Code Violation .......................... S
2.
Errored Second ....................... .S
3.
Severly Errored Second .......... S
4.
Code Violation .......................... L
5.
Errored Second ........................ L
6.
Severly Errored Second .......... L
7.
Unavailable Second.................. L
8.
Code Violation .......................... P
9.
Errored Second ........................ P
10.
Sev Errored Second ................. P
11.
Unavailable Second.................. P
© 2003, ADTRAN, Inc.
Short
Loop
Out-of-Service, Unassigned
Enabled
Off
Off
Total Access
®
3000/3010 System Manual