DLP-744
Page 6 of 12
Perform Steps Below in the Order Listed
7. Provision SCU in the Expansion Shelves (Client)
1.) Access the menus for the Expansion Shelf (Client) by either connecting
through the front panel craft port (see DLP-715) or by Telnet session if
connected to the LAN.
2.) From the Main Menu, select System Controller.
3.) From the System Controller Main Menu, select Provisioning.
4.) From the Provisioning Menu, select General.
5.) From the General Menu, select Interbank Comm. Mode.
6.) Set Interbank Comm. Mode to Client.
7.) Verify that the HST LED on the SCU front panel has gone out.
8.) Press <Esc> until you have returned to the SCU Provisioning Menu.
9.) Select TL1.
10.) From the TL1 Menu, select Client Shelf Management.
11.) From the Client Shelf Management Menu, select Expansion Shelf.
12.) You will be automatically directed to the Unit Number Menu where the Unit
Number for the shelf will need to be added. After selecting the Unit Number,
the SCU will automatically verify that the Unit Number does not conflict with
the Unit Number of any other shelf. If there is a conflict, a message will be
displayed and another Unit Number will need to be selected. The first
subtended shelf is typically assigned the Unit Number "2" and the second
subtended shelf is typically assigned the Unit Number "3."
13.) Verify that the Target ID (TID) has been automatically updated and is the
same as the Target ID (TID) that was entered at the Intelligent NE (Host)
Shelf SCU.
14.) Press <Esc> to return to the Total Access Main Menu.
15.) Repeat section 1.2.7 above for each of the Expansion Shelves.